17th Edition Consumer Units 
In the UK, domestic and small commercial or public installations usually have single-phase supplies at 230V (nominal standard). The main distribution boards in these installations are called consumer units (CUs), though they may be known as fuse boxes; older consumer units used fuses until the advent of mini-circuit breakers (MCBs). A consumer unit normally has a single horizontal row of fuses or MCBs, though some older units grouped four fuses in a square arrangement. For two-rate supplies (standard/off-peak), a second CU may be added (stacked). Multiple CUs are also found in larger premises.

Larger commercial, public, and industrial installations generally use three-phase supplies, with distribution boards which have twin vertical rows of breakers. Larger installations will often use subsidiary distribution boards.

In both cases, modern boards handling supplies up to around 100 A (CUs) or 200 A (distribution boards) use circuit breakers and RCDs on DIN rail mountings. The main distribution board in an installation will also normally provide a main switch (known as an incomer) which switches the phase and neutral lines for the whole supply. (n.b., an incomer may be referred to, or sold as, an isolator, but this is problematic, as it will not necessarily be used as an isolator in the strict sense.)

Modern CU
A typical new domestic CU used as a main panel may have from 6 to 24 ways for devices (some of which may occupy two ways), and will be split into two or more sections (e.g. a non-RCD section for alarms etc., an RCD-protected section for socket outlets, and an RCD-protected section for lighting and other built-in appliances). Secondary CUs used for outbuildings usually have 1 to 4 ways plus an RCD.
A modern dual RCD consumer board



Older CUs
a 16th ediition consumer unitRecent (pre-17th edition wiring regulations) CUs would not usually have RCD protected sections for anything other than socket outlets, though some older CUs used RCD Incomers. Before the 1990s RCDs (and split busbars) were not standard in CUs.

 

 

 

 

 

 

RCD protection types

With the introduction of the recent 17th Edition IEE Wiring Regulations consumer units in the UK must provide RCD protection to all cables embedded in walls excepting high integrity circuits such as those for burglar alarms or smoke alarms.

Consumer units have different methods of protecting circuits. A dual split-load consumer unit can be arranged as follows:

RCDRCD 1
Upstairs Lights,
Downstairs Final Ring Main,
Garage Sockets,
Shower

RCD 2
Downstairs Lights,
Upstairs Sockets,
Cooker,
Heating,

By alternating the circuits like this, power will always be present on one floor if either RCD trips out.

Another way to protect circuits under the 17th Edition IEE Wiring Regulations is by fitting Residual Current Circuit Breaker With Overload (RCBOs) to every circuit although this can be a very costly method.

Fuse Boxes usually use cartridge or rewirable fuses with no other protective device, and basic 4-ways boxes are very common. Some older boxes are made of brown-black bakelite, sometimes with a wooden base. Although their design is historic, these were standard equipment for new installs as recently as the 1980s, so they are very common. Fuseholders in these boxes may not provide protection from accidental contact with live terminals.

The popular 4-way fusebox usually has two lighting and two socket circuits, with heavy or sustained loads such as immersion heater and oven on a socket circuit. This arrangement is not recommended practice today, as electricity usage has substantially grown in the last 20 years, but it is still in some existing installations. Larger boxes with more ways will have separate fuses for large loads such as immersion heater, oven and shower.

Circuit breaker retrofits
Some of these fuseboxes have had their fuse carriers replaced with plug-in miniature circuit breakers. These retrofit MCBs are typically rated at 3kA breaking capacity, but many homes or properties have prospective short circuit currents as high as 6kA. Fault currents of over 3kA are thus interrupted by the incomer fuse, should they ever occur, and the MCB would not survive.[citation needed]

Historic fuseboxeshistoric fuse box
A small number of pre-1950 fuseboxes are still in service. These should be treated with caution because exposed live parts are common on these boxes. The installations they supply will not meet modern standards for electrical safety. Another characteristic of very old installations is that there may be two fuses for each circuit; one on the live and one on the neutral. In rare instances, old ring circuits may be encountered with no less than 4 15 A fuses per ring, one on each of L and N, and this duplicated for each of the 2 feeds for the ring.

Inside a UK distribution boarddiagram of a 17th edition consumer unit
This picture shows the interior of a typical 12-position UK distribution panel. The incoming live cable connects to the busbars via a main dual pole isolator switch on the left of the panel. This isolator switches both the live and the neutral feeds on and off at the same time. Power comes in to the top of the isolator and so out of the bottom must come twp cables to go behind the DIN rail and into the top of both RCD's. In this diagram the neutral comes out of the bottom of the isolator and into a central neutral terminal bar but often, just as the live, two cables will come out of the bottom of the isolator behind the DIN bar and into the top of the RCD's. Once the RCD's become live and they in turn are asitched on power comes out of the bottom of the RCD's and into the bus bars to which all the other MCB's are connected. The cables to the individual circuits are then fixed into to the top of the MCB's. In the finished consumer unit, even once the cover is removed there will be a plastic shield covering these bus bars so as to give extra protection.

Things to note.
The MCB's will be in descending order of value, i.e., 40amp, 32amp, 32amp, 16amp and a 6amp. And that the MCB's on the left hand side of the board will have their corresponding neutrals attached to the left of the two neutral bars. It is important to note that if you have even one of the neutrals from the left side going into the right hand bar the board will never power up properly and you will always have nuisance tripping if you can even get it to stay on for longer than a few seconds.

The incoming earth wire connects directly to the earth bar on the top right of our diagram to which all the other earths are connected to.



Spotlights / Lighting 

fitting_downlights 

Full / Partial Rewires

Considering a Full or Part Rewire? You need a fully qualified electrician

The life expectancy of a new electrical installation is approximately 20 Years. There are many factors that affect the life expectancy i.e. the type of wiring and how it was used. As the life of an installation is pretty long, it is easy to forget that it will eventually need replacing.

Electrical rewiring involves the replacement of old, dangerous or non-compliant electrical equipment i.e. cables, fittings, distribution boards (fuse boxes) and Auber Electrical are very experienced in this type of electrical work.

Contemplating a complete rewire is a huge undertaking but very worthwhile in updating your home electrics to meet current regulations and most importantly, safety standards. A rewire will also make the electrical wiring in your home more capable of meeting today's demands in terms of electrical appliances.

If your electrical wiring was installed many years ago (especially pre 1970's) it is likely that the installation was not planned to accommodate the level of electrical equipment that you have today.
Old wiring is a potential fire hazard. If you are considering a full or part rwire, then call Auber Electricial for a fully qualified Part P NICEIC approved electrician
 
To rectify or upgrage old domestic wiring call Auber Electrical
You may not have enough sockets in the right places. You may use extension leads which may cause your appliances to overload electrical circuits. You may also want additional lighting or power to a garage or shed.

DJL Electrical can update all this for you in one go and will make the experience as stress-free as possible for you. We offer free no obligation quotations for work ranging from a full rewire to a selection of small alterations and repairs and all our work is fully certified.

How safe is your wiring your home? In less time than you may think, the electrics in your home can become damaged or worn through general wear and tear. It’s important to get them inspected and tested to check they’re still safe to use. 
 
 

Does your house need a rewire?

Many houses in the UK still have old wiring. This is not only unsafe and a potential fire hazard but is also less efficient than modern systems. It can also affect the resale value of your house, as old wiring almost certainly is highlighted as a major problem during a survey.

If you have old wiring in your house, for example fabric or rubber covered flex you should seriously consider having a complete rewire.

Here at DJL Electrical we can completely redesign your electrical system to include sufficient socket outlets located in the right places to accommodate your needs, a state of the art consumer unit to replace your old fuse box which will contain residual current devices and circuit breakers. Rewiring a house is a major undertaking, but rest assured we will carry out the work as quickly and efficiently as possible.

Installing a new fuse box and wiring conforms with current British Standards

Modern fuse box,
light switch & wire
 
Old wiring and sockets can be a hazard. Contact Auber Electrical for a part or full rewire of your home

Old fuse box, light switch & cable
Do you need a rewire - here is an initial checklist
  • Does your fuse box have replaceable fuse wire?
  • Do your plugs or sockets get hot or have scorch marks?
  • Do fuses blow regularly?
  • Do you have to use extension leads and adaptors?
  • Do you have lights that use the old, twisted type flex?
  • Do you have rubber covered flex?
  • Do you have round pin plugs and sockets?
  • Are your cables missing an earth cable?                     
  • Do you use electrical equipment outdoors?
  • Has your wiring been checked in the last 10 years?
Full Rewire

A full rewire involves replacing all cables, fittings and distribution equipment. Cables can be chased into the walls & completely hidden. Alternatively a rewire can involved a surface rewire where the cables are hidden in mini trunking fitted onto the surface of the walls.

 
Part Rewire

A part rewire may be the replacement of a section of the installation or just updating of the fuse boxes, fittings or cables to upgrade an installation to the current regulations and efficiency.

What are the benefits of completely rewiring your home?
  • You can feel reassured that the wiring in your home is clean, new and safe
  • You can feel assured your wiring meets the demands you make on it
  • If you decide to sell your home, a recent rewire may well help your sale to go through
  • There should be no nasty surprises when surveys (incl a review of the electrics) take place
  • You get rid of all those trailing cables
  • You get rid of extension leads and reduce the risk of overloading electrical circuits
  • Imagine having power exactly where you want it!
We offer quotations for domestic rewires free of charge with no obligation and all our work is comprehensively certified, as well as under warranty.
 
Making Your Rewire Less Stressful

It is helpful if you consider rewiring your home before you undertake a lot of decorating as creating new sockets and moving lights and switches does create mess and often redecorating becomes necessary in some rooms.

Some customers ask how they should prepare their home in advance of our arrival. Obviously the easiest time to have a rewire is before you move in! However, if you are living in the property it helps if you can reduce general clutter and large items of furniture are moved a short distance from the wall.

Contact DJL Electrical today for a free quotation of all your electrical rewiring needs
 


 